Poster Session No. 5 - LC-MS Sample Preparation; High Throughput Analysis
00- Impact of Side Reactions Involving Strong Cation Exchange SPE Mechanism on Bioanalytical Assay Accuracy by Using LC-MS/MS
Catherine Fontaine; Jean-Nicholas Mess; Milton Furtado; Fabio Garofolo
Algorithme Pharma Inc., Laval (Montreal), Quebec , CANADA
00- The Retention Behavior of Phospholipids Leading to the Elimination of Matrix Effect in LC-MS/MS Using Reverse-Phase Silica SPE
Mathieu Lahaie; Milton Furtado; Fabio Garofolo
Algorithme Pharma Inc., Laval (Montreal), Quebec , CANADA
00- Efficiency, Reproducibility, Accuracy and Linearity Evaluation of Filtration Plates during Protein Precipitation to Remove Phospholipids in Bioanalysis by LC-MS/MS
Catherine Dicaire; Milton Furtado; Fabio Garofolo
Algorithme Pharma Inc., Laval (Montreal), Quebec , CANADA
00- Selection of Buffer Additives for Liquid-Liquid Extraction (LLE) Procedure to Remove Matrix Effect Due to Phospholipids in LC-MS/MS
Melanie Bergeron; Mathieu Lahaie; Milton Furtado; Fabio Garofolo
Algorithme Pharma Inc., Laval (Montreal), Quebec , CANADA
00- Details Two dimensional online Solid-Phase Extraction combined with Liquid Chromatography - Mass Spectrometry
Martin Sibum; Emile Koster
Spark Holland Inc., Plainsboro , NJ WPN 351
00- Increased Bioanalytical Throughput Using Selective Phospholipid Depletion
Craig Aurand1; An Trinh2; Hillel K. Brandes1; David S. Bell1; Michael Ye1
1Supelco/ Sigma Aldrich, Bellefonte , PA; 2Supelco, Bellefonte, PA
00- Comparison of Plasma and Whole Blood Extraction using Resin-based Mixed-mode Cation Exchange SPE with LC-MS/MS Analysis
Elena Gairloch(1); Lee Williams(2); Helen Lodder(2); Rhys Jones(2); Richard Calverley(2); Steve Plant(2); Steve Jordan(2); Claire Desbrow(2); Joanna Caulfield(2); Gary Dowthwaite(2)
1. Biotage, Charlottesville, VA, USA. 2. Biotage GB Limited, Cardiff, United Kingdom
00- Comparison of Liquid-liquid Extraction (LLE) and Supported Liquid Extraction (SLE):- Equivalent Limits of Quantitation with Smaller Sample Volumes
Lee Williams; Helen Lodder; Rhys Jones; Steve Jordan; Claire Desbrow; Gary Dowthwaite; Joanna Caulfield; Richard Calverley
Biotage GB Limited, Cardiff , United Kingdom
00- Extraction of Melamine from Various Matrices using Resin-based Mixed-mode Cation Exchange SPE and Analysis with LC-MS/MS
Lee Williams1; Elena Gairloch2; Rhys Jones1; Helen Lodder1; Steve Jordan1; Richard Calverley1; Claire desbrow1; steve Plant1; Gary Dowthwaite1; Joanna Caulfield1
1Biotage GB Limited, Cardiff , United Kingdom ; 2Biotage, Charlottesville, VA
00- Phospholipid Removal: A Comparison between Traditional Liquid-liquid Extraction (LLE) and Supported Liquid Extraction (SLE) Using LC-MS/MS Analysis
Lee Williams1; Mike Lindenmuth2; Rhys Jones1; claire Desbrow1; Joanna Caulfield1; Gary Dowthwaite1; Richard Calverley1; Steve Jordan1; Helen Lodder1
1Biotage GB Limited, Cardiff , United Kingdom ; 2Biotage, Charlottesville, VA
00- Integrated workflow to design methods and analyze data in large-to-extremely-large scale SRM experiments
Amol Prakash1; Reiko Kiyonami1; Alan E. Schoen2; Huy Nguyen2; Scott Peterman2; Andreas F Huhmer2; Mary F Lopez1; Bruno Domon3
1ThermoFisher Scientific, Cambridge , MA; 2Thermo Fisher Scientific, San Jose, CA; 3ETH Zurich, Zurich, SWITZERLAND
00- On line sample extraction technique vs traditional sample preparation methods for LC-MS toxicology screening
Marta Kozak; Guifeng Jiang; Subodh Nimkar
Thermo Fisher Scientific, San Jose , CA
00- High Throughput Quantitative Sample Analysis Using an Integrated Multiplex LC-MS System Combined with On-Line SPE
Min J. Yang; David M. Cox; Adrian Taylor; Peter Kovarik; John Gibbons
MDS Analytical Technologies, Concord, Canada
00- Improved Bioanalysis of Antidepressants from Plasma Using Non-Drip Filtration Plates
Eugene Chang, Dave Jones and Ritu Arora
Varian, Inc. , 25200 Commercentre Dr., Lake Forest, CA 92630, USA
00- Automated Extraction of Pharmaceutical compounds in Plasma
William Hudson; Yung-Lin Chen
Varian, Inc., Lake Forest , CA